netcdf ocean-time-series/Stellwagen/CHINCOTEAGUE/10283Aexo-a.nc { dimensions: time = UNLIMITED; // (5850 currently) lat = 1; lon = 1; depth = 1; variables: int time(time=5850); :long_name = "Time"; :units = "True Julian Day"; :type = "EVEN"; :epic_code = 624.0; // double int time2(time=5850); :long_name = "Time2"; :units = "msec since 00:00 GMT"; :type = "EVEN"; :epic_code = 624.0; // double double lat(lat=1); :units = "degrees_north"; :long_name = "Latitude"; :epic_code = 500.0; // double :datum = "NAD83"; double lon(lon=1); :units = "degrees_east"; :long_name = "Longitude"; :epic_code = 502.0; // double :datum = "NAD83"; double depth(depth=1); :positive = "down"; :long_name = "Depth"; :axis = "z"; :units = "m"; :epic_code = 3.0; // double double Bat_106(time=5850, lon=1, lat=1, depth=1); :long_name = "Battery voltage (v)"; :units = "V"; :epic_code = 106.0; // double :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 4.9; // double :maximum = 6.0; // double :_FillValue = 1.0E35; // double double fDOMRFU(time=5850, lon=1, lat=1, depth=1); :long_name = "Fluorescent dissolved organic matter"; :units = "Relative fluorescence units (RFU)"; :epic_code = " "; :sensor_model_number = "599104-1"; :sensor_serial_number = "14D101570"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 2.07; // double :maximum = 13.2; // double :_FillValue = 1.0E35; // double :note = "Recursively filtered fDOMRFU data to eliminate data where increases by > 5 units in a single time step"; double fDOMQSU(time=5850, lon=1, lat=1, depth=1); :long_name = "Fluorescent dissolved organic matter"; :units = "(Quinine Sulfate equivalents (QSU)"; :epic_code = " "; :sensor_model_number = "599104-1"; :sensor_serial_number = "14D101570"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 6.12; // double :maximum = 39.73; // double :_FillValue = 1.0E35; // double :note = "Recursively filtered fDOMQSU data to eliminate data where increases by > 10 units in a single time step"; double CHLrfu(time=5850, lon=1, lat=1, depth=1); :long_name = "Chlorophyll A"; :units = "Relative fluorescence units (RFU)"; :epic_code = ""; :sensor_model_number = "599103-01"; :sensor_serial_number = "14A103656"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 0.09; // double :maximum = 10.11; // double :_FillValue = 1.0E35; // double :comment = "Chlorophyll probe, wiped"; :note = "Recursively filtered CHLrfu data to eliminate data where increases by > 10 units in a single time step"; double Fch_906(time=5850, lon=1, lat=1, depth=1); :long_name = "Chlorophyll A"; :units = "ug/L"; :epic_code = 906.0; // double :sensor_model_number = "599103-01"; :sensor_serial_number = "14A103656"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 0.37; // double :maximum = 26.85; // double :_FillValue = 1.0E35; // double :comment = "Chlorophyll probe, wiped"; :note = "Recursively filtered Fch_906 data to eliminate data where increases by > 25 units in a single time step"; double BGAPErfu(time=5850, lon=1, lat=1, depth=1); :long_name = "Blue green algae phycoerythrin"; :units = "Relative fluorescence units (RFU)"; :epic_code = ""; :sensor_model_number = "599103-01"; :sensor_serial_number = "14A103656"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 0.3; // double :maximum = 10.55; // double :_FillValue = 1.0E35; // double :comment = "Chlorophyll probe, wiped"; :note = "Recursively filtered BGAPErfu data to eliminate data where increases by > 15 units in a single time step"; double BGAPE(time=5850, lon=1, lat=1, depth=1); :long_name = "Blue green algae phycoerythrin"; :units = "ug/L"; :epic_code = ""; :sensor_model_number = "599103-01"; :sensor_serial_number = "14A103656"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 0.78; // double :maximum = 29.69; // double :_FillValue = 1.0E35; // double :comment = "Chlorophyll probe, wiped"; :note = "Recursively filtered BGAPE data to eliminate data where increases by > 30 units in a single time step"; double T_28(time=5850, lon=1, lat=1, depth=1); :long_name = "Temperature"; :units = "C"; :epic_code = 28.0; // double :sensor_model_number = "599870-01"; :sensor_serial_number = "14D103804"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 16.795; // double :maximum = 29.526; // double :_FillValue = 1.0E35; // double :comment = "ITS-1990 Standard"; double C_51(time=5850, lon=1, lat=1, depth=1); :long_name = "Conductivity"; :units = "S/m"; :epic_code = 51.0; // double :sensor_model_number = "599870-01"; :sensor_serial_number = "14D103804"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 4.023490000000001; // double :maximum = 5.25567; // double :_FillValue = 1.0E35; // double :data_cmnt = "Conductivity sensor failed on this deployment."; :note = "No drift/fouling correction applied.; Conductivity sensor began to fail on or about 22-Sep-2014 22:15:00, and values replaced with fill value after this time, "; double SpC_48(time=5850, lon=1, lat=1, depth=1); :long_name = "Specific conductance"; :units = "mS/cm"; :epic_code = 48.0; // double :sensor_model_number = "599870-01"; :sensor_serial_number = "14D103804"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 43.3264; // double :maximum = 48.4239; // double :_FillValue = 1.0E35; // double :comment = "temperature compensated to 25C"; :data_cmnt = "Conductivity sensor failed on this deployment."; :note = "No drift/fouling correction applied.; Conductivity sensor began to fail on or about 22-Sep-2014 22:15:00, and values replaced with fill value after this time, "; double S_41(time=5850, lon=1, lat=1, depth=1); :long_name = "Salinity"; :units = "Practical salinity units (PSU)"; :epic_code = 41.0; // double :sensor_model_number = "599870-01"; :sensor_serial_number = "14D103804"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 27.89; // double :maximum = 31.49; // double :_FillValue = 1.0E35; // double :data_cmnt = "Conductivity sensor failed on this deployment."; :note = "No drift/fouling correction applied.; Conductivity sensor began to fail on or about 22-Sep-2014 22:15:00, and values replaced with fill value after this time, "; double OST_62(time=5850, lon=1, lat=1, depth=1); :long_name = "Oxygen percent saturation"; :units = "%"; :epic_code = 62.0; // double :sensor_model_number = "599100-01"; :sensor_serial_number = "14E100493"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 72.3; // double :maximum = 214.5; // double :_FillValue = 1.0E35; // double :comment = "ROX Optical DO sensor, wiped"; double DO(time=5850, lon=1, lat=1, depth=1); :long_name = "Dissolved oxygen"; :units = "mg/L"; :epic_code = ""; :sensor_model_number = "599100-01"; :sensor_serial_number = "14E100493"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 4.86; // double :maximum = 14.95; // double :_FillValue = 1.0E35; // double :comment = "ROX Optical DO sensor, wiped"; double Turb(time=5850, lon=1, lat=1, depth=1); :long_name = "Turbidity"; :units = "Nephelometric turbidity units (NTU)"; :epic_code = ""; :sensor_model_number = "599101-01"; :sensor_serial_number = "14D104083"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = -0.28; // double :maximum = 47.59; // double :_FillValue = 1.0E35; // double :comment = "wiped turbidity probe"; :note = "Recursively filtered Turb data to eliminate data where increases by > 100 units in a single time step"; double pH_159(time=5850, lon=1, lat=1, depth=1); :long_name = "pH"; :units = " "; :epic_code = 159.0; // double :sensor_model_number = "599701"; :sensor_serial_number = "14E100756"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 7.693944263977197; // double :maximum = 8.655118823730692; // double :_FillValue = 1.0E35; // double :note = "apply linear drift/fouling correction. "; :data_cmnt = "Use pH data with caution!! probe has limited life span"; double pHmV(time=5850, lon=1, lat=1, depth=1); :long_name = "pH"; :units = "mV"; :epic_code = " "; :sensor_model_number = "599701"; :sensor_serial_number = "14E100756"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = -113.8; // double :maximum = -63.7; // double :_FillValue = 1.0E35; // double double Press(time=5850, lon=1, lat=1, depth=1); :long_name = "Pressure"; :units = "pounds per square inch (psi)"; :epic_code = ""; :sensor_serial_number = "14C101632"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 1.672; // double :maximum = 2.517; // double :_FillValue = 1.0E35; // double :note = "Pressure sensor zeroed in air prior to initial deployment in July 2014"; double D_3(time=5850, lon=1, lat=1, depth=1); :long_name = "Depth"; :units = "m"; :epic_code = 3.0; // double :sensor_serial_number = "14C101632"; :sensor_depth = 1.4500000000000002; // double :height_depth_units = "m"; :initial_sensor_height = 0.15; // double :minimum = 1.156; // double :maximum = 1.744; // double :_FillValue = 1.0E35; // double :positive = "down"; :axis = "z"; double dn(time=5850); :long_name = "Matlab datenum"; :units = "Days since Jan-0-0000 00:00:00"; double P_1ac(time=5850, lon=1, lat=1, depth=1); :name = "pressure (corrected for atmospheric)"; :long_name = "pressure (corrected for atmospheric)"; :standard_name = "sea_water_pressure_due_to_sea_water"; :units = "dbar"; :initial_instrument_height = 0.15; // double :minimum = 1.118923999999998; // double :maximum = 1.8681175000000003; // double :_FillValue = 1.0E35; // double :note = "Corrected for variations in atmospheric pressure using record from WAHV2 and weather station at mooring 1031"; // global attributes: :SciPi = "N. Ganju"; :PROJECT = "USGS Coastal Marine Geology Program"; :EXPERIMENT = "Estuarine physical response"; :DESCRIPTION = "site CB10, Tingle Is"; :DATA_SUBTYPE = "MOORED"; :DATA_ORIGIN = "USGS WHCMSC Sed Trans Group"; :COORD_SYSTEM = "GEOGRAPHIC"; :Conventions = "PMEL/EPIC"; :MOORING = "1028"; :WATER_DEPTH = 1.6; // double :WATER_DEPTH_NOTE = "(meters), nominal depth"; :latitude = 38.15852; // double :longitude = -75.21156; // double :magnetic_variation = -11.74; // double :Deployment_date = "14-Aug-2014"; :Recovery_date = "14-Oct-2014"; :DATA_CMNT = "Conductivity sensor failed during this deployment. "; :platform_type = "SWIP"; :DRIFTER = 0.0; // double :POS_CONST = 0.0; // double :DEPTH_CONST = 0.0; // double :WATER_MASS = "Chincoteague Bay, VA/MD"; :VAR_FILL = 1.0E35; // double :institution = "United States Geological Survey, Woods Hole Coastal and Marine Science Center"; :institution_url = "http://woodshole.er.usgs.gov"; :initial_instrument_height = 0.15; // double :DELTA_T = 900.0; // double :INST_TYPE = "YSI EXO"; :serial_number = "14D100014"; :FILL_FLAG = 1.0; // double :note = ""; :VAR_DESC = "Battery V:fDOM RFU:fDOM QSU:Chlorophyll RFU:Chlorophyll �g/L:BGA-PE RFU:BGA-PE �g/L:Temp �C:Cond �S/cm:SpCond �S/cm:Sal psu:ODO % sat:ODO mg/L:Turbidity FNU:pH:pH mV:Press psi a:Depth m"; :COMPOSITE = 0.0; // double :CREATION_DATE = "21-Mar-2016 14:23:54"; :start_time = "14-Aug-2014 14:15:00"; :stop_time = "14-Oct-2014 12:30:00"; :history = "Corrected pH data for drift/fouling, Remove spikes/bad data and replace with fill value, Trimmed using trunc_cdfNative, SVN $Revision: 3342 $ to select records in the range 178 to 6027. :created using ysiEXO2ncNative in Matlab 8.3.0.532 (R2014a)."; }